<bdo id="jgume"><var id="jgume"><menu id="jgume"></menu></var></bdo>
  • <tr id="jgume"></tr>
      <menuitem id="jgume"></menuitem>
          <tr id="jgume"></tr>

            Load Sensor

            Overload, illegal dumping, unauthorized using of vehicles, fuel theft, illegal operation have been growing problems with the fast development of truck logistics. At one time, the administrators had been helpless and obviously traditional solutions such as truck scale are not ideal for its high cost, high error and failure rate.Based on the issues above, Soway Tech Ltd designs and produces a brand new load sensor, SAHX series, which has a longer life-expectancy and higher accuracy. 

             

            Load sensor                                            

            Load sensor

            SAHX-120B

            Output signal

            Accurency
            Range scope

            Working temperature(℃)

            角度载重传感器-深圳信为研发  产品 (热门产品 - 3*) 

            0.5-4.5V/CAN/RS485

            ±2%(F.S)

            0-120℃

            -40~ 70

             

            Load sensor

            Output style

            linear error(%)

            Working temperature(℃)

             https://my.diytrade.com/diyep/siteMain/page/editor?rp_em=2&rp_ene=Page&rp_eid=7839132&pageID=7839132&page=page/editor#

            - No load/full load/overload

            ±5

            -20~ 85

            -Continuous analog quantity

            ±5

            -20~ 85

            It can detect the no-load, full load, overload and partial load state of the muck car, mud truck, coal truck, ore car and other cars.

             

            Position sensor/lift sensor
             

            Model Principle

            Contact

            form

            output method

            Power supply type

            action distance(mm)

             

            P119

            Reed

            switch

            principle

            Normally open/normally closed optional

            ON/OFF switch signal high and low level

            24V DC以下

            Power supply 39-41 (iron plate)
            83-85 (non-iron plate parallel test)

            SPH119

            Hall

            principle

            / 0~5V 9~28 VDC non-iron plate parallel test 0~25mm
             

             

            Airtight sensor SP1191 series

            Model

            Supply

            voltage

            Contact

            form

            trigger distance output method Operating temperature range action distance

            trigger method

            SP1191-A

            12~30 VDC

             

            ≤15mm

            (face to face trigger)

            No trigger, output 5V, green light is always on


            When triggered, the output is 2.5V, and the green light is dim


            The thread is cut, the output is 0V, and the light is off

            -30~+120℃ ≤100mm

            (Parallel movement after face-to-face trigger)

            magnet trigger

            SP1191-B

            12~24 VDC

            Type A

            contact
            (normally open)

            ≥20mm Switch


            When triggered, turn on


            No trigger, disconnected

            -25~+80℃   magnet trigger
            SP1191-C   Form A contact (normally open)   High and low level output


            Trigger (when airtight): high level light is on


            Leave (when open): low level light off

            -25~+80℃    

            It can detect the lifting and lifting of dump truck, muck truck, dump truck, garbage truck bucket and car.

             

             

            Positive and reverse tachometric transducer    

            Positive and reverse tachometric transducer

            SPH3A0-10B-V-MEP10

            output mode

            Supply voltage

            Detector detection distance(mm)

            working environment

            Open-collector output
             

            DC 5V~24V

             

             5-10

            Temperature-20~80℃

            Humidity≤90%

                                                

            Temperature and humidity measurement

             

            ST116/117

            Analog signal temperature sensor

            Supply voltage
            Measuring range

             

            Accuracy of detection

            Output signal

             

            Housing

            3.0~5.5 VDC

            -40 ℃ ~ +85 ℃

            ±1 ℃

            (0 ℃~+70 ℃)

            linear voltage
            :0℃-500mV,10mV/℃
            Stainless steel 316
            ±0.5℃(-10~+85℃) Single bus data communication

              Widely used in cold chain logistics transportation, agriculture, forestry, meteorological environment, greenhouse, laboratory, Internet of things system and other industries as well as climate room, warehouse

            Storage, ship, dock, flower cultivation, pharmacy, supermarket warehouse, museum, fog spray intelligent control system and other places.

            T119 Temperature Sensor

            Supply voltage
            Measuring range

             

            Accuracy

            Output signal

             

            Protecion Grade

            5 VDC

            -40 ℃ ~ +80 ℃

            ±0.5 ℃

            (0 ℃~70℃ )

             

            Modbus RS485 IP67

             

            ST118 Temperature and
            humidity sensor

            Supply voltage

            Measuring range

            Output signal

            Housing

            5 VDC(Current≤15mA)

            Temperature:±0.2℃(0~+60℃)

            Humidity:2%(25℃)

            RS485(MODBUS)

            Flame retardant engineering plastics UL94-V0

            oil measurement sensor   

            Reed tube type oil level sensor

            output mode

            input/output range

            Outgoing way

            Installation methods

            Material Action point spacing measurement accuracy Range scope Float Working temperature

            Resistive output
            (no transmitter)

            input:no

            output:KΩ

            Second line out

            (A junction box can be added)

            Thread, flange

             

            SUS304

            SUS316

            5mm-10mm ±5mm

            ±10mm

            0.1m-1m NBR Float -40℃~+85℃
            Voltage output
            (with transmitter)

             
            input range:12V(24V)

            output range:0-5V(1-10V)

            error range:0.3V

            Three line out

            (A junction box can be added)
            Current output
            4-20mA
            (with transmitter)
            input:24V

            output:4-20mA

            Add a junction box for three wires

                                                         

            Fuel consumption
            meter

            HOCM03

            Accuracy of measurement

            Flow range

            Working temperature

            Product material Working voltage Digital output (one can be selected) Oil circuit interface

            ±1%

            10-450 L/H

            -20℃~80℃

            aluminum 24V DC RS232 interface (1 way)

            RS485 interface (1 way)

            M14*1.5

             

            国产Av一区二区三区蜜芽
            <bdo id="jgume"><var id="jgume"><menu id="jgume"></menu></var></bdo>
          1. <tr id="jgume"></tr>
              <menuitem id="jgume"></menuitem>
                  <tr id="jgume"></tr>